Futaba GY611 Instrukcja Użytkownika Strona 26

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 43
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 25
26
D
ATA
S
ETTING
When Using a T9Csuper Transmitter
The Gyro Mixing (GYRO SENS) function lets operator perform a gain adjust-
ment at each condition switch position.
[GY611 Settings]
Select the gyro operation mode at the GY611 Mode screen. (AVC, NOR, or
CMT)
[Transmitter Settings]
Gyro Mixing function:
1. Activate the function at the transmitter Gyro Mixing (GYRO SENS) setup
screen.
2. Select the condition switch (Cond.) for the sensitivity selection.
3. Set the NORM, IDL1, IDL2, IDL3, and HOLD gains.
(The following page shows a setting example in the CMT mode.)
[Sensitivity Display]
The gain display indicates the actual gain at the GY611 normal screen dis-
play. The following shows the relationship between transmitter and gyro set-
ting.
[Relationship between transmitter and gyro setting]
Transmitter settings:
NOR AVC
100% - 0% - 100%
Normal mode
AVCS mode
Normal mode AVCS mode
Actual gain: 100% - 0% - 100%
NOR:
AVC:
CMT:
GY611 mode
settings:
Przeglądanie stron 25